Experimental and Computational Fluid Dynamic Analysis of External Gear Pump
- Dipen ArvindKumar Rana
- Nirmal Kumar
CFD gear rotor, experiment of external gear pump test rig
CFD analysis is applying for to know flow behavior inside the pump that cannot be captured in physical testing. Prepare experimental setup for generate experimental data. From experimental find the pump operating pressure at maximum rpm. When applying simulation with the experimental inlet boundary condition and rotation, it has generated profile. This profile was very accurate with measure quantity so, simulation validate accurately. With this feedback simulate for 4 psi deliver pressure which is required to circulate in punching machine. This gives good agreement with experimental result.
Dipen ArvindKumar Rana, Nirmal Kumar. "Experimental and Computational Fluid Dynamic Analysis of External Gear Pump".INTERNATIONAL JOURNAL OF ENGINEERING DEVELOPMENT AND RESEARCH ISSN:2321-9939, Vol.2, Issue 2, pp.2474-2478, URL :https://rjwave.org/ijedr/papers/IJEDR1402188.pdf
Volume 2 Issue 2
Pages. 2474-2478